- RIUKAI TECHNOLOGY has 25+ years of experience in the field of environmental testing equipment testing to meet the needs of our customers.
Cold Temperature Test Chamber
Cold Temperature Test Chamber
Model: RK-TD-1000
Main Parameters:
Name:Cold Temperature Chamber
Brand:RIUKAI
Temperature fluctuation: ≤± 0.5 ℃
Temperature uniformity: ≤± 2.0 ℃
Temperature deviation: ≤± 2.0 ℃
Temperature range: B:0℃→+150℃;R:-20℃→+150℃;L:-40℃→+150℃;U:-60℃→+150℃;S:-70℃→+150℃
Temperature change rate: 3 ℃ / min, 5 ℃ / min, 10 ℃ / min, 15 ℃ / min, 20 ℃ / min, 25 ℃ / min (optional)
The Cold Temperature Test Chamber is designed to simulate extreme temperature and humidity conditions for testing the durability, performance, and reliability of various products, materials, and components. It is widely used in industries like automotive, electronics, aerospace, materials science, and pharmaceuticals, where products need to be evaluated under rigorous environmental conditions. The test chamber offers flexible and customizable settings to meet specific testing requirements, ensuring precise simulation of both high and low-temperature environments.
1. Temperature Range
-
Range: B: 0°C → +150°C | R: -20°C → +150°C | L: -40°C → +150°C | U: -60°C → +150°C | S: -70°C → +150°C
-
Description: The cold temperature test chamber supports a wide range of temperature settings, from a minimum of -70°C in the S model to a maximum of +150°C across all models. This broad temperature range is essential for simulating various environmental conditions that products may encounter, ensuring their stability and reliability in real-world scenarios, from extreme cold to high heat.
2. Humidity Range
-
Range: 20% R.H ~ 98% R.H (non-standard customization options: 10% R.H ~ 98% R.H, 5% R.H ~ 98% R.H)
-
Description: The chamber provides excellent humidity control with the ability to simulate different levels of moisture in the environment. The standard range is 20% to 98% relative humidity (R.H.), but customizable options allow the chamber to simulate even drier conditions, as low as 5% or 10% R.H., catering to a wide variety of test scenarios.
3. Temperature Change Rate
-
Options: 3°C/min, 5°C/min, 10°C/min, 15°C/min, 20°C/min, 25°C/min (optional)
-
Description: The chamber offers a customizable temperature change rate, allowing users to select the speed at which the temperature increases or decreases. With options ranging from 3°C/min to 25°C/min, the chamber can simulate both gradual and rapid thermal changes. This is particularly useful for testing products under thermal shock conditions, where quick temperature transitions are crucial to evaluate material behavior under stress.
4. Temperature / Humidity Fluctuation
-
Temperature fluctuation: ≤ ± 0.5°C
-
Humidity fluctuation: ≤ ± 2% R.H
-
Description: High precision in temperature and humidity control is ensured, with fluctuations kept to a minimum. The temperature fluctuation is limited to ≤ ±0.5°C, while humidity fluctuations are restricted to ≤ ±2% R.H. This consistency ensures accurate, repeatable test results, which are essential for quality assurance and reliable performance in extreme environmental conditions.
5. Cooling Mode
-
Options: Air-cooled or water-cooled (optional)
-
Description: Depending on the specific requirements of the test, users can choose between an air-cooled or water-cooled system. The air-cooled system is more energy-efficient and suitable for most applications, while the water-cooled system provides enhanced cooling performance for more demanding applications. This flexibility allows users to select the best cooling method based on the size and thermal load of the test chamber.
Common Applications:
-
Automotive Testing: To evaluate how vehicles, components, and materials perform under low temperatures.
-
Electronics: Testing the resilience of electronic components such as batteries, semiconductors, and circuit boards in freezing conditions.
-
Aerospace: Ensuring that aerospace materials and equipment can withstand the harsh conditions found in high-altitude or polar regions.
-
Pharmaceuticals: To test the stability of drugs and medical devices in cold storage conditions.
-
Packaging: Assessing how packaging materials perform in cold environments, ensuring they don’t become brittle or ineffective.
| Parameter | Specification |
|---|---|
| Model | RK-TD-1000 |
| Inner Tank Volume | 1000 L |
| Inner Chamber Dimensions (W×H×D) | 1000 × 1000 × 1000 mm |
| Overall Dimensions (W×H×D) | 1200 × 1900 × 1850 mm |
| Temperature Range | B:0℃ → +150℃;R:-20℃ → +150℃;L:-40℃ → +150℃;U:-60℃ → +150℃;S:-70℃ → +150℃ |
| Humidity Range | 20% R.H ~ 98% R.H (Customizable options: 10% R.H ~ 98% R.H, 5% R.H ~ 98% R.H) |
| Temperature Change Rate | 3 / 5 / 10 / 15 / 20 / 25 ℃/min (Optional) |
| Temperature / Humidity Fluctuation | Temperature Fluctuation: ≤ ±0.5℃;Humidity Fluctuation: ≤ ±2% R.H |
| Temperature / Humidity Uniformity | Temperature Uniformity: ≤ ±2.0℃;Humidity Uniformity: ±2% R.H,-3% R.H |
| Temperature / Humidity Deviation | Temperature Deviation: ≤ ±2.0℃;Humidity Deviation: ±3% R.H |
| Heating Time (Rate) | Approx. 3 ~ 4 ℃/min (Customizable as required. Temperature Shock Chambers can achieve 5 ~ 50 ℃/min) |
| Cooling Time (Rate) | Approx. 1 ℃/min |
| Cooling Mode | Air-cooled or Water-cooled (Optional) |
| Load | Simulated heating load customized according to actual demand |
| Inner Chamber Material | 304 Stainless Steel |
| Outer Casing Material | Stainless steel plate with baked paint finish or Stainless Steel |
| Thermal Insulation Material | High-Density Polyurethane Foam |
| Refrigeration System | Imported first-tier, well-known brand compressor |
| Safety Protections | No-fuse switch, Compressor overpressure & overheat protection, Overcurrent protection, Overtemperature protection, Overload protection, Dry-burn protection, Water shortage protection, etc. |
| Controller | Touch screen controller, selectable languages: Chinese/English/Japanese/Korean. Operates in Custom/Program mode. |
| Standard Accessories | Φ50mm test port, 2 pcs of 304 stainless steel grating shelves |
| Operating Environment | +5℃ ~ +35℃;Atmospheric pressure: 86kPa ~ 106kPa;Level, vibration-free surface;Relative humidity ≤ 85% R.H |
| Power Supply | 220V AC 3-phase 50Hz or 380V AC 3-phase 50Hz |
| Remarks | Optional: High & Low Temperature test only (without humidity function). Final specifications subject to the confirmed proposal. |




.webp)
1-1.jpg)